If you’ve ever walked through a medium-voltage (MV) electrical substation, you’ve probably noticed large, grey boxy devices wrapped around power lines, standing tall alongside circuit breakers and transformers. For years, I was that guy who walked right past them, assuming they were just another piece of “electrical furniture” — until a client of mine, an industrial plant manager, called me in a panic. Their MV current transformer (CT) had failed, and they needed a replacement fast, but their maintenance crew couldn’t shut down the line long enough to install a traditional solid-core CT. That’s when I first learned about split core MV CTs, and how they’re changing the game for MV electrical maintenance and retrofits. As a supplier of medium-voltage instrument current transformers, I’ve spent thousands of hours explaining these devices to engineers, plant managers, and electricians, and I’m here to break down exactly how they work, why they’re different, and why they might be the perfect fit for your next project. Mv Instrument Current Transformer

First, let’s ground ourselves in what a current transformer does, because if you don’t get that, you’ll never understand why split core MV CTs matter. CTs are safety and measurement workhorses: their whole job is to step down high alternating current (AC) from power lines to a low, safe level (usually 1A or 5A) that instruments, meters, and protection relays can handle. Without CTs, you’d be trying to hook a 10,000-amp power line directly to a $5,000 protection relay — that’s a recipe for disaster, both for your equipment and your team. Traditional solid-core MV CTs have been the standard for decades: you remove a section of the power line, run it through a solid iron core coil, then seal and mount it. The problem? If you need to replace, inspect, or move the CT, you have to shut down the entire line — sometimes for hours, even days, if you’re working with a 15kV or 33kV feeder. That’s where split core design comes in.
A split core MV CT gets its name from its most defining feature: its iron core is not one solid piece. It’s split into two halves, hinged on one side and latched tight on the other. To install it, you don’t need to touch the power line at all — you just pry the two halves open, snap them around the live power cable, and tighten the latch until the core is closed. No line shutdown, no cutting conductors, no days of downtime. That’s the selling point everyone talks about, but there’s a lot more going on under the hood that makes these devices work reliably for MV applications. Let’s dive into the inner workings, step by step.
First, the core and winding assembly. At the heart of any CT is a ferromagnetic core, usually made of laminated silicon steel. For split core MV CTs, this core is split along a precisely machined seam — the key here is that the seam has to be almost perfectly tight when latched. Even a tiny gap, like a 0.1mm space between the two halves, can cause magnetic flux leakage, which distorts the current output and makes measurements inaccurate. That’s why cheap split core CTs fall short for MV applications: they use thin, low-grade steel and sloppy machining that leads to flux leakage. The ones we supply use grain-oriented silicon steel, which is optimized for magnetic performance, and precision-machined seams that are calibrated to close with less than 0.05mm gap — enough to fit tightly around a cable, but not enough to cause meaningful flux loss.
Wrapped around this core is the secondary winding. Unlike the primary winding in a solid-core CT, which is the power line itself (the primary conductor passes through the core), split core MV CTs don’t have a built-in primary winding. The power line acts as the primary turn — that’s right, a single conductor passing through the core counts as one turn of the primary. That’s why when you snap the core around a 4160V feeder, the power line becomes the primary, and the wound coil around the split core becomes the secondary. This is a critical difference: it means you don’t have to run multiple turns of heavy gauge wire through the core, which would be impossible on an active line. The secondary winding is tightly wound with copper wire, encased in a moisture-resistant, high-voltage insulating material — usually cross-linked polyethylene (XLPE) or epoxy — to withstand the 15kV, 25kV, or even 35kV environments common in MV setups.
Next, the latching and sealing mechanism. It’s not just a simple hook and latch. For MV split core CTs, the latch system has to meet strict electrical safety standards. When the core is closed, the latch creates a continuous magnetic path — that’s non-negotiable. If the latch is loose, the core can separate slightly, which not only causes measurement errors but also can create a dangerous arc flash hazard. All the split core MV CTs we supply have a spring-loaded, torque-controlled latch that clicks into place when the core is fully closed, and a built-in sensor (we’ll talk about that later) that confirms the core is latched securely before the CT will output a valid signal. The entire assembly is sealed in a hard, weatherproof polymer housing, rated for outdoor use in temperatures from -40°C to 85°C, so they can be installed on substations, overhead lines, or industrial plants without extra enclosures.
Now, let’s get into the electrical principle that makes CTs work: Ampère’s Law. For anyone who slept through physics class, Ampère’s Law says that the magnetic field around a conductor is proportional to the current flowing through it. When current runs through the power line (the primary conductor inside the split core), it generates a magnetic field that cuts through the secondary winding wrapped around the core. Faraday’s Law of Induction turns that changing magnetic field into an electrical current in the secondary winding. The ratio of primary current to secondary current is called the turns ratio, and it’s standardized for MV applications: common ratios are 100:5, 200:5, up to 5000:5. For example, a 200:5 split core MV CT will output 5 amps when 200 amps are flowing through the power line — that’s exactly the low level your meters and relays are designed to accept.
Here’s where split core MV CTs have to work a little harder than solid-core ones to maintain accuracy. Because there’s a seam in the core, some magnetic flux leaks out instead of traveling through the whole core. We compensate for this by using a higher-quality core material (grain-oriented steel has lower core loss than standard steel) and calibrating each unit in our factory to adjust for that flux loss. Every split core CT we supply is tested at 10% to 120% of its rated current, to ensure accuracy within 0.2% — which is equivalent to most solid-core MV CTs, and more than enough for metering and protection applications. We also test for insulation resistance at 2x the rated voltage, so you never have to worry about a breakdown even on high-current MV feeders.
One of the most common questions I get is: can split core MV CTs be used for protection relays, not just metering? A few years back, a utility engineer asked me that exact question, and they were surprised to hear that yes, they can — as long as they’re rated for the right accuracy class. A lot of people think split core designs are only for temporary installations, but modern split core MV CTs have accuracy classes of 0.5S and 10P20, which are approved for overcurrent protection, ground fault protection, and other relay applications. The 10P20 rating means the CT will maintain accuracy within ±10% even when the primary current is 20 times the rated current — which is exactly what you need for a relay to trip correctly during a fault. The only caveat: if you’re installing a split core CT on a feeder that has to meet strict regulatory requirements for energy metering (like tax-grade metering), you’ll want to make sure it’s calibrated to meet ANSI C12.20 or IEC 62053 standards, which all our units do.
Another key feature of modern split core MV CTs is the core position sensor. I mentioned this earlier, and it’s one of the biggest safety upgrades over old split core designs. Before, technicians could accidentally close the core with a small gap, or forget to latch it completely, leading to bad measurements or even a magnetic arc. Our split core MV CTs have a built-in reed switch or hall effect sensor that sends a signal to the connected meter or relay only when the core is fully latched and sealed. If the core comes loose, the sensor cuts the output signal, which triggers an alarm at the control panel. That means you don’t have to rely on visual inspection after installation — the device itself will tell you if it’s working properly. It’s a small feature, but it’s saved our customers hundreds of dollars in incorrect meter readings and safety incidents.
Now, let’s talk about real-world use cases, because theory is great, but these devices shine in practical scenarios. Last year, a food processing plant needed to upgrade their energy meters to track demand for their new production line, but their existing MV feeder ran to a processing building that was already at full capacity — shutting down the line to install a solid-core CT would have cost them $150,000 in lost production per day. They used split core MV CTs instead: our technicians installed six units on the live feeder in a single afternoon, no shutdown, and the energy data they got was accurate enough to meet their utility’s billing requirements. Another common use case is retrofits: utilities often have older substations with solid-core CTs that are failing, but they don’t have the infrastructure to install new ones without major construction. Split core CTs let them replace old units line-free, reducing retrofit costs by up to 60% compared to solid-core installations.
That said, split core MV CTs aren’t for every application. They’re ideal for retrofits, temporary installations, or any project where downtime is costly, but for permanent installations on new lines, solid-core CTs are still more cost-effective long-term — as long as you can afford the downtime to install them. You also have to make sure you’re getting a unit rated for your specific voltage and current: a 15kV split core CT won’t work on a 35kV feeder, and a 100:5 unit can’t handle 1000 amps. That’s why it’s important to work with a supplier who can help you select the right rating, not just sell you a one-size-fits-all device.
If you’re reading this and wondering if a split core MV CT is right for your next project, the most important thing to remember is: not all split core CTs are created equal. Many low-cost imports on the market have uncalibrated cores, thin insulation, and no core position sensors, which can lead to inaccurate readings, safety hazards, and even failure in high-voltage environments. The split core MV CTs we supply are designed for long-term use in industrial and utility applications, with factory calibration for accuracy, weather-sealed housings, and compliance with ANSI and IEC standards.

Whether you’re an engineer looking to upgrade a substation, a plant manager trying to avoid costly downtime, or a contractor working on a temporary measurement project, split core MV CTs offer a flexible, safe, and accurate alternative to traditional solid-core designs. If you’re ready to explore which split core MV CT is right for your application, get in touch to discuss your requirements. We’ll help you select the correct rating, walk you through installation best practices, and make sure you get a device that meets your performance and safety needs.
MV Instrument Voltage Transformer References
- ANSI Standard C57.13, Standard Requirements for Instrument Transformers
- IEC Standard 61869-2, Instrument Transformers – Part 2: Current Transformers
- "Split-Core Current Transformers: A Guide to Selection and Application," Electrical Construction & Maintenance, 2022
- "Magnetic Flux Leakage in Split-Core Current Transformers," IEEE Transactions on Power Delivery, vol. 34, no. 2, 2019
Dalian Xin’anyue Electric Power Equipment Co., Ltd.
Dalian Xin’anyue Electric Power Equipment Co., Ltd. is one of the most reliable mv instrument current transformer manufacturers and suppliers in China, featured by quality products and good price. Please rest assured to wholesale durable mv instrument current transformer in stock here from our factory. We also accept customized orders.